Field Review - Addition / Alteration - #200 - 2nd Floor (demising into #200 and #202) Interior alterations on the 2nd floor to demise the existing general office space #200 into two units to be #200 and #202 and to provide tenant improvements on suite #200 only, in this existing commercial building on this site. Scope of work: Construct a new demising wall between two suites, add a new corridor. Demolish all partitions walls, doors, finishes on suite #202 to leave into shell space, electrical and sprinkler work to suit. REVISION #1: Revise common corridor wall AND update engress door for suite #202, update door size for suite #200 and remove T-Bar panels. Increase in project cost of $10,000 (from $150,000) - Sept 4/24 - LLL Architectural Schedule B submitted by Nicholas Waissbluth, Architect, AIBC, 604.612.5095 Separate permit is required for future tenant improvement or to change the use on suite #202. Building Sprinklered – Separate sprinkler permit required for proposed sprinkler work. Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing).