Commercial / Multi-Res Alteration · BP126606
(Landlord work)Remove demising wall (installed with out permit) between units 2 and 3, remove interior partition walls, remove kitchen sink and return to shell space. Permit required for future tenant improvements. Building Classification: 1995 BCBC - 3.2.2.45 (reclassified under 1998 BCBC 3.2.2.57), Building Area 4180m2, Sprinklered with fire alarm system, non-combustible construction, 2 storey with mezzanine, facing 1 street. Floor assemblies 2 hrs Fire Separation/ Resistance Rating. Mezzanine: 1hr FS/FRR. Roof: 1hr Fire Separation/Fire Resistance Rating (FS,FRR). Supporting Assemblies: All loadbearing walls, columns & arches shall have fire resistance ratings not less than required for the supporting assemblies. Adjoining Group F3 (parkade) with 1.5 hr Fire Separation/Fire Resistance rating complete with vestibules at exits into parkade. Equivalencies: Refuse chute, Exiting Storage rm, water curtain exit exposure.
Other addresses listed in this application: 5801 TURNER ROAD.