Commercial / Multi-Res Alteration · BP126828
"Change of Use" to Group D and interior renovations (Andritz Automation) 531.88 m2, work includes 14 relocated & 6 new sprinkler heads, plumbing fixtures added, partition walls added Building Classification: 1995 BCBC - 3.2.2.45 (reclassified under 1998 BCBC 3.2.2.57), Building Area 4180m2, Sprinklered with fire alarm system, non-combustible construction, 2 storey with mezzanine, facing 1 street. Floor assemblies 2 hrs Fire Separation/ Resistance Rating. Mezzanine: 1hr FS/FRR. Roof: 1hr Fire Separation/Fire Resistance Rating (FS,FRR). Supporting Assemblies: All loadbearing walls, columns & arches shall have fire resistance ratings not less than required for the supporting assemblies. Adjoining Group F3 (parkade) with 1.5 hr Fire Separation/Fire Resistance rating complete with vestibules at exits into parkade. Equivalences: Refuse chute, Exiting Storage rm, water curtain exit exposure. Dec 3/21: Revision - angle one corner of electrical room
Other addresses listed in this application: 5801 TURNER ROAD.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.