Perform load calc for sauna heater install. Demand load determined to be acceptable. Install 2c8 heatex for 8kw sauna heater from main 200amp elec panel to sauna location in basement with 2p50 amp breaker. Sleeve cable with metallic liquid tight flex for mechanical protection, install led lighting under bench. Sauna heater has built in controls so dies not require any additional controls as per CEC
Application address
2122 SPRING RD
Source-reported status
COMPLETED
Source record created
Issued date
Source final date
Source: Victoria — Issued permits — 2023-2025. Contains information licensed under the Open Government Licence – City of Victoria.
These are municipal application records. Their status and dates do not establish current construction progress. Associated addresses do not establish a verified parcel history.
About this project
Permit value (CAD): 1500.00
Permit issued: 2025-01-02