installed 30amp 240v circuit for heat pump. Cut above and below panel and fished wire down into open ceiling main floor. Continued to run cable into crawl space along joist, strapping all the way. Entered into a 4x4 junction box and spliced with a teck whip going outside to disconnect. Mounted disconnected and entered cable with teck connector and installed surge protector and unit whip. Terminated the disconnect. Entered cable into panel using a dry connector, terminated bond and conductors into a 30amp 240v breaker