Building permit — Addition / Alteration · BP-2022-01815
Field Review - Addition / Alteration - Exterior and interior alterations to this one family dwelling building on this site. Exterior work to infill a window on the west elevation, new windows and doors on the north and south elevations. Scope of work includes new interconnecting stairs, new insulation in the attic and main floor, reconfiguring the interior layout, replacing the fireplace and new lighting throughout. REVISION #1: - To change the proposed basement layout - To add structural drawings per DBI request B.Wong - May 5/23 OK for Field Review per W.Wong Notes: - This building is not sprinklered. - Schedule B, Structural & Geotechnical, Li Qing Shi, 778-772-7508. - REUP Submitted by Doug Martin, 604-614-7985. Scope of work to include energy upgrade in accordance with Article 11.2.1.4 of the 2019 Vancouver Building By-law and as per the Energy Efficiency Upgrade Details noted in the Energuide Report. - Install interconnected, hardwired, 120 volt smoke alarms with a carbon monoxide detection, battery back-up and silencing feature in accordance with 9.10.19. of VBBL 2019.