Building permit — Addition / Alteration · BP-2022-02422
Enquiry Centre - Addition / Alteration - Interior alteration to change the basement into a secondary suite in this existing single family with a laneway house. Scope of Work: Remove parition wall and add new kitchen to the basement secondary suite Ok for Field Review as per J. Bal, May 13th, 2022 Note: - No strata-titling will be permitted. - An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. - Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and within 5m outside each sleeping areas on each storey as per Building Bylaw 9.10.19. - Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. & Bulletin 2007-007-BU/EL - Ceiling height to be a min. 6ft 5" over 80% of the suite area and all exit routes - Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times