Building permit — Addition / Alteration · DB-2023-02687
Enquiry Centre - Addition / Alteration - Interior alterations and a change of use from single detached house to single detached house with secondary suite with one parking space in the detached garage with vehicular access from the street. Scope of work: - Install new utility room, new A/C, removed stair case to lower fl. This is not a sprinklered building Note: - No strata-titling will be permitted. - An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. - Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and within 5m outside each sleeping areas on each storey as per Building Bylaw 9.10.19.3 - Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2 Upgrade work under Part 11 (based on value of work – energuide related Part 11.2.1.4.) - Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes - Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times All unsafe guards and handrails to be upgraded to the satisfaction of the Chief Building Official.
Source: Vancouver — Issued permits — 2023-2025. Contains information licensed under the Open Government Licence – Vancouver.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.
Sign in to comment.
No comments on this page.