Building permit — Addition / Alteration · DB-2023-03935
Enquiry Centre - Addition / Alteration - Interior alterations to change the use from Single Detached House to Single Detached House with Secondary Suite. Ok for Field Review per J. Zhang, Oct 30th, 2023 This is not a sprinklered building IA-2022-00320 - No strata-titling will be permitted. - An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. - Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and within 5m outside each sleeping areas on each storey as per Building Bylaw 9.10.19.3 - Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2 - Upgrade work under Part 11 (based on value of work – energuide related Part 11.2.1.4.) - Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes - Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times - All unsafe guards and handrails to be upgraded to the satisfaction of the Chief Building Official.
Source: Vancouver — Issued permits — 2023-2025. Contains information licensed under the Open Government Licence – Vancouver.