Building permit — Addition / Alteration · DB-2023-02805
Field Review - Addition / Alteration - Interior alterations to this existing one family dwelling to change the use to a one family dwelling with a secondary suite. Scope of work includes: 1) Addition of a kitchen on the lower floor 2) Addition of fire separation between secondary suite and primary dwelling Related to CF-2023-002535 Revision #1: To revert back to a single detached home and remove the unauthorized secondary suite on the lower floor Notes: - This building is not sprinklered. - No strata-titling will be permitted. - An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. - Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and on each storey as per Building Bylaw 9.10.19. - Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. - Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes - Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times