Building permit — Addition / Alteration · BP-2018-00904
High Density Housing / Commercial - Addition / Alteration - Building Permit for DP-2017-00811 Interior alterations to address work without permit changes made pursuant prior development permit DE416911. Proposed work includes restoration of fire separation at exit stair, validation of kitchen equipment layout and reconfiguration of the interior layout. Building Review Branch Notes: See related BP-2018-00356 for exterior rooftop patio application. 1. Class 2 and Class 4 Cooking Operation. 2. Grease laden vapour shall not be generated by the Class 2 cooking equipment. Post a sign on the hood, "Cooking causing grease-laden vapours is not allowed Exhaust system is designed for steam and heat removal only". Type II Hoods (Heat and Steam Removal Only) to be design, constructed, and installed in accordance with VBBL and referenced standards. 3. Class 4 cooking operations (Grease-Laden Vapours). 4. Commercial kitchen exhaust system to NFPA 96 (Type 1 Self-contained hood).