Building permit — Addition / Alteration · BP-2021-01994
Field Review - Addition / Alteration - Exterior and interior alterations to change the layout of the secondary suite for this existing one family dwelling with secondary suite with two off street parking pad spaces provided having vehicular access from the rear lane Exterior work to install 1 new window on north elevation and to replace and/or enclose existing windows Scope of work includes removal of unauthorized room addition under rear deck CF-2020-013039 Structural, Architectural & Geotechnical Schedule B - Xue Li Chen - 778-235-5447 OK For Field Review per Ally C - May 3/21 OK for BP per S.Chang Note: No strata-titling will be permitted. An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and within 5m outside each sleeping areas on each storey as per Building Bylaw 9.10.19. Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. Upgrade work under Part 11 (based on value of work – energuide related Part 11.2.1.4.) Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times
Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.