Building permit — Addition / Alteration · DB-2021-01776
Field Review - Addition / Alteration - CF-2020-004439 and CF-2021-002938 - Interior alterations and change of use this existing two-storey, one family dwelling to a one family dwelling with a secondary suite on the 1st storey. Upgrading for suite as per Special Inspection IA-2021-00049. Scope of work includes: raise roof over suite entrance at the rear, new door for mech room and electrical work. Infill stair opening on 2nd floor, interconnecting stairs not removed - to be used as storage with new door on 1st floor for suite. OK for Field Review as per R. Astorino April 23, 2021. Notes: ~ Energy Upgrade: Exempt < $20,000. ~ Building Not Sprinklered – No sprinkler permit required. ~ No parking provided on site, required on-site parking relaxed to "0", as per Sonia Erikson April 23, 2021. ~ Interconnected, hard-wired smoke alarms with carbon monoxide detection, battery back-up and silencing feature are to be installed in every bedroom and one on every floor which must be located in the hallway when the bedrooms are served by a hallway. ~ No strata-titling will be permitted ~ This is a two storey building pursuant to the Zoning and Development Bylaw. ~ An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. ~ Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times.
Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.