Building permit — Addition / Alteration · DB-2024-01436
Field Review - Addition / Alteration - Interior alterations and change of use from one family dwelling to one family dwelling with secondary suite to this existing single-family house on site. Validate unauthorized suite related to CF-2023-009947. Repair the wall damage caused by the illegal grow-op to the scope of work related to CF-2023-010736. OK for field review as per O. Luo, Apr 19th, 2024 Note: This building is sprinklered. District Building Inspector to determine if a separate sprinkler permit is required for all related work. No strata-titling will be permitted. An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and in hallways serving sleeping units on each storey as per Building Bylaw 9.10.19. Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times. Headroom to be minimum 1950mm over 80% of the suite area and all egress routes. This permit is for alterations as shown in plans only. Any unauthorized work on this site, existing or otherwise, is neither recognized nor approved and may be subject to enforcement action.
Source: Vancouver — Issued permits — 2023-2025. Contains information licensed under the Open Government Licence – Vancouver.