Project · Public

Building permit — Addition / Alteration — 4010 PRINCE ALBERT STREET, Vancouver, BC V5V 4J3

Source: Vancouver — Issued permits — 2023-2025

Low Density Housing - Addition / Alteration - Exterior and interior alterations to add a new third floor with covered porch area facing E 24th Av and to validate the rear deck of this existing two-storey 2-unit character Multiple…

Listed on FolioProjects
2026-11-27
Location
4010 PRINCE ALBERT STREET, Vancouver, BC V5V 4J3
Application number
BP-2025-01082
Source-reported status
Issued

Application status does not establish construction activity or completion.

Share, broadcast and print
Open broadcast feed

Source information and freshness

Vancouver — Issued permits — 2023-2025 · Last checked 2026-11-27T04:35:28.417578+00:00

Checking a source does not confirm that its records reflect current construction or approvals. Meaningful changes appear in Activity.

Original source record

Contains information licensed under the Open Government Licence – Vancouver. Licence

Summary totals updated 2026-11-27 04:44:11.448416+00. Recent changes appear after the next refresh.

Public Broadcast · screens & websites

Shows only publicly available records. Private records are excluded, even when you are signed in.

Launch Broadcast ↗

Municipal application details

Building permit — Addition / Alteration · BP-2025-01082

Low Density Housing - Addition / Alteration - Exterior and interior alterations to add a new third floor with covered porch area facing E 24th Av and to validate the rear deck of this existing two-storey 2-unit character Multiple Conversion Dwelling with one unit being a secondary suite on this corner flanking with lane site. Revision #1: 1. Interior layout changes 2. Exterior change to upper floor covered porch size 3. Change in roofing material 4. Lowered roof peak 5. Change in window locations for the addition, no change in sizes 6. Water main connection location shifted 7. Update REUP form offset point upgrades to: heat pump, upgrade ventilation controls, level 2 EV charger, minor air sealing Revision #2: 1. To RE & RE the existing wood burning fireplace 2. To increase the depth of the rear deck skirt roof 3. To add an air handler to the attic space 4. To reconstruct the chimney Related to DP-2024-00669 & m/a DP-2025-00915 Building to be sprinklered in accordance with NFPA 13D standards. South face to have exterior sprinklers conforming to NFPA 13 standards. Schedule B, Structural, Henry S.N Hsu, P. ENG, 604-322-7158 - Interconnected smoke alarms to be installed on each storey including basements, in each sleeping room and in a location between the sleeping room and the remainder of the storey and if the sleeping room is served by a hallway, the smoke alarm to be located in the hallway. Installed by permanent connections to an electrical circuit in conformance with 9.10.19. Provided with battery backup and manual silencing devices which will silence the alarm in conformance with 9.10.19.6. - Carbon Monoxide detectors to be provided in accordance with 9.32.4.2. - No strata titling will be permitted. - Dedicated 3' wide firefighter access path with overhead clearance of 2m to be maintained at all times. - An annual Vancouver Business Licence must be obtained prior to the rental

Application address
4010 PRINCE ALBERT STREET, Vancouver, BC V5V 4J3
Source-reported status
Issued
Source record created
Issued date

Source: Vancouver — Issued permits — 2023-2025. Contains information licensed under the Open Government Licence – Vancouver.

Source data licence and terms of use ↗

View municipal application ↗

These are municipal application records. Their status and dates do not establish current construction progress. Associated addresses do not establish a verified parcel history.

About this project

Permit value (CAD): 310000.00

Type of work: Addition / Alteration

Property use: Dwelling Uses

Specific use: Multiple Conversion Dwelling

Area: Kensington-Cedar Cottage

Permit issued: 2025-06-20

Permit number created: 2025-03-07

HueFlux feedback

Recorded project feedback. These responses do not establish property condition or represent the whole community.

No feedback yet

Share your view using the controls below.

Positive feedback
Negative feedback

Project polls

Answer specific questions about this project and view the results the owner chooses to share.

View project polls

Poll answers are measured separately from HueFlux feedback.

References

No reference links have been added.

Focus areas

No focus areas have been added.

Comments

New comments are public while this project is public. Earlier members-only comments remain restricted.

Sign in to comment.

No comments on this page.