Building permit — Addition / Alteration · BP-2021-06072
Field Review - Addition / Alteration - #100 Interior alterations to provide improvements for this new retail tenant in unit #100 of this existing building on this site. New Tenant: Freshii Ok for field review as per K.Kang November 19, 2021 Note: - No seating in the lobby area is permitted. - This building is sprinklered. DBI to determine on site if a separate permit is required. - DBI to determine on site if Schedule B, Structural, is required. - Energy Upgrade: E2 - Lighting - Upgrade to incorporate Automatic Full OFF (per 9.4.1.1.(h) of ASHRAE 90.1-2016. - Schedule A & Schedule B (Mechanical/Plumbing), Satwik Shetty, P.Eng, 778-360-2153 - Schedule B (Electrical) - Abdul Ei-Haddad, P.Eng, 778-360-2153 - Class-5 Cooking Operations (No Hood): Appliances are less than or equal to 6 kW. Cooking procedures producing significant grease laden vapors, or significant heat or steam are not permitted. Where complaints are received by the Health Department such as mould from too much moisture, over-heating in the work environment, objectionable odours, or build up of grease or smoke residue, the owner or manager is responsible to make the required corrections, such as a menu change or applying for a building permit to comply with the appropriate Class of Cooking Operation.
Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.