Building permit — Addition / Alteration · DB-2019-05361
Field Review - Addition / Alteration - CF-2019-012812 - Exterior and interior alterations to change of use from one family dwelling to one family dwelling with a secondary suite on this site. Scope of work includes to relocate the front door entrance from north to east side, construct a 4'x8' landing and 6'x8' sunken patio on the south side and remove an unauthorized kitchen in the basement OK for field review as per Jamie Zhang 3464 Tanner St - Existing Principal Dwelling (west portion of the basement and 1st storey) 3466 Tanner St - Secondary Suite (east portion of the basement) Note: - No strata-titling will be permitted. - An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. - Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and within 5m outside each sleeping areas on each storey as per Building Bylaw 9.10.19. - Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. & Bulletin 2007-007-BU/EL - Upgrade work under Part 11 (based on value of work – energuide related Part 11.2.1.4.) - Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes
Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.