Building permit — Addition / Alteration · DB-2020-02410
Field Review - Addition / Alteration - To permit interior alterations and to change the Use to a One Family Dwelling with Secondary Suite on this inside with lane site. 2 car garage at rear to remain with access from the lane. Scope to include: Legalization of the Secondary Suite in the basement. OK for Field Review per A.Campbell & S.Erichsen - Aug.6.2020 #1 - 2876 McGill St - Existing Principal Dwelling (1st storey, south-east portion of the basement) #2 - 2876 McGill St - Secondary Suite (north and south-west portion of the basement) 1) No strata-titling will be permitted. 2) An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. 3) Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and within 5m outside each sleeping areas on each storey as per Building Bylaw 9.10.19. 4) Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. & Bulletin 2007-007-BU/EL 5) Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes