Project · Public

Building permit — Addition / Alteration — 250 W PENDER STREET, Vancouver, BC V6B 1S9

0 visitors / 30 days

Source: Vancouver — Issued permits — 2020-2022

Field Review - Addition / Alteration - Exterior alterations at Dunsmuir St and Hamilton St to provide improvements to the landscaping and to replace a failed waterproof membrane beneath the plaza protecting Level 1 of the existing School…

Listed on FolioProjects
2026-11-28
Location
250 W PENDER STREET, Vancouver, BC V6B 1S9
Application number
DB-2020-00640
Source-reported status
Issued

Application status does not establish construction activity or completion.

Share, broadcast and print
Open broadcast feed

Source information and freshness

Vancouver — Issued permits — 2020-2022 · Last checked 2026-11-28T23:00:24.509078+00:00

Checking a source does not confirm that its records reflect current construction or approvals. Meaningful changes appear in Activity.

Original source record

Contains information licensed under the Open Government Licence – Vancouver. Licence

Summary totals updated 2026-11-28 23:37:35.478113+00. Recent changes appear after the next refresh.

Public Broadcast · screens & websites

Shows only publicly available records. Private records are excluded, even when you are signed in.

Launch Broadcast ↗

Municipal application details

Building permit — Addition / Alteration · DB-2020-00640

Field Review - Addition / Alteration - Exterior alterations at Dunsmuir St and Hamilton St to provide improvements to the landscaping and to replace a failed waterproof membrane beneath the plaza protecting Level 1 of the existing School - (A2) (Vancouver Community College) "Heritage A Primary" building on this site. Scope of work includes: demolish - planters, retaining walls, drainage system, pavers, building strip adjacent to sidewalks. Build new planters, install new pavers, footings, slab, building strip and trench system. New landscaping and new plaza lighting. No interior alterations permitted under this permit. Note: Landscape drawings are included with approved drawings and are complete with grading and planting plan superseding landscape drawings previously approved by Development Permit. OK For Field Review per A.Campbell & S. Voskaskis, Feb 19, 2020 Notes: ~Energy Upgrade: L2 - Lighting - Exterior Lighting Control (per 9.4.1.7 of ASHRAE 90.1-2016) ~See combined Development and Building Permit, DB-2020-01113 for New Bicycle Storage and Access Gates. ~Schedule A CRP, Schedule B Architectural and Schedule D Building Envelope submitted by T. Shimbashi, Architect AIBC., Tel: 604 568-6990. ~Schedule B Structural submitted by Lihua (Phoebe) He, P. Eng of Stantec Consulting Ltd., Tel: 604 696-8216. ~Schedule B Plumbing submitted by B. M. Yammine, P.Eng. of Flow Consulting Group Inc., Tel: 604 609-0500. ~Schedule B Electrical submitted by S. I. Fernandez Alarcon, P.Eng. of Flow Consulting Group Inc., Tel: 604 609-0500.

Application address
250 W PENDER STREET, Vancouver, BC V6B 1S9
Source-reported status
Issued
Source record created
Issued date

Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.

Source data licence and terms of use ↗

View municipal application ↗

These are municipal application records. Their status and dates do not establish current construction progress. Associated addresses do not establish a verified parcel history.

About this project

Permit value (CAD): 800000.00

Type of work: Addition / Alteration

Permit category: Renovation - Commercial/ Mixed Use - Lower Complexity

Property use: Institutional Uses

Specific use: School - University or College

Area: Downtown

Permit issued: 2020-06-23

Permit number created: 2020-02-19

HueFlux feedback

Recorded project feedback. These responses do not establish property condition or represent the whole community.

No feedback yet

Share your view using the controls below.

Positive feedback
Negative feedback

Project polls

Answer specific questions about this project and view the results the owner chooses to share.

View project polls

Poll answers are measured separately from HueFlux feedback.

References

No reference links have been added.

Focus areas

No focus areas have been added.

Comments

New comments are public while this project is public. Earlier members-only comments remain restricted.

Sign in to comment.

No comments on this page.