Building permit — Addition / Alteration · BP-2022-04932
Field Review - Addition / Alteration - #102 Interior alterations to provide tenant improvements for a new office tenant, to expand into an adjacent unit on the main level, combining #102 & #103 (retaining #102), in this existing commercial building. Scope of work: Demolish the demising wall between the 2 units, remove/construct partition walls, doors, new flooring and electrical work. TENANT: Watson Advisors Inc Building Sprinklered – Building inspector to determine on site if a separate sprinkler permit is required. E2 - Lighting - Upgrade to incorporate Automatic Partial OFF (per 9.4.1.1.(g) of ASHRAE 90.1-2016)\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing). All energy upgrades will be checked during inspections stage. It is the applicant’s responsibility to identify and note all required upgrades including energy upgrades on their BP drawings at BP stage.
Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.