Building permit — Addition / Alteration · BP-2020-02789
High Density Housing / Commercial - Addition / Alteration - Building Permit for DP-2018-00942 Interior and exterior alterations, relocation, change of major occupancy of the entire building from one family dwelling (group C) to commercial building with Medium-Hazardous Industrial and Office (Group F2 & D) with a bike storage (Group F3), and an addition of 1,209.10 SF to the rear of this existing 2-storey plus basement Heritage C building on this site and to stratify the lot. Sch A, Arch B, Stru B, Mech B, Plmb B, Fire B, Elec B, Geotech B, & Sch D are submitted. ******THIS PERMIT HAS BEEN ISSUED UNDER THE REQUIREMENTS OF VBBL 2019******** Building Review Branch Notes: - Building to conform to NECB 2015. F4, S4, N4, A4, & E6 upgrades are required. Accessible design is in compliance with VBBL 3.8.3.2 to 3.8.3.21. - Building to be sprinklerred to NFPA 13. Existing wood stud on north and south sides shall be shall be protected by exterior sprinkler as per VBBL 11.5.1.1.(11). - Operable skylights shall conform to VBBL 9.7.5.4. - All controls and outlets except in the crawlspace shall conform to VBBL 3.8.2.6. - Signs and indicators for access shall be provided as per VBBL 3.8.2.10.(1)&(2). - Submetering is required as per VBBL 10.2.2.9. - Building shall be tested for airtightness testing at time of final inspection as per VBBL 10.2.2.21. Processed during the COVID-19 Pandemic.
Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.