Building permit — New Building · BP-2018-03000
High Density Housing / Commercial - New Building - To construct a new Two-Family Dwelling building with two Lock-Off Units and common electrical room (Building DE; $413,690). Stru B & Geo B are submitted. See BP-2018-02861 for BP fees. See main building permit BP-2018-03001 for documents, comments, and time entry. ***THIS PERMIT HAS BEEN ISSUED UNDER THE REQUIREMENTS OF VBBL 2014 & AMENDMENTS (BYLAW #12013)*** Building Review Branch Notes: - Building to be sprinklered to NFPA 13D. Bathrooms and closets shall be sprinklered as per VBBL 9.10.14.4.(7). - At least one entrance door of each dwelling shall be equipped with a beveled threshold not more than 13 mm above the floor level except for entrance doors serving basements per VBBL 3.8.5.2.(1)(b). - Refuse enclosure must not be connected to the building. - All new windows, doors and skylights shall conform to AAMA/WDMA/CSA101/I.S.2/A440, NAFS and VBBL 9.7.5. - Building shall comply with Energy Efficiency requirements per VBBL 10.2.1.5. - OK to apply 9.10.15.5. for exposing building face construction only as per Matthew Lam on Dec 16, 2021. 9.10.14.5.(6) is still applicable for noncombustible projection. REVISION #1(Mar 11, 2022): Related to M/A DP-2021-00875 - Modified crawlspace wall assembly. - Added sprinkler valve location. - Changed window sizes and kitchen layout. - Changed rated exterior walls and exterior door closures to unrated walls and self-closing doors.
Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.