Building permit — Addition / Alteration · DB-2024-01765
Field Review - Addition / Alteration - 2257 E 35th Ave Interior alterations to convert this duplex with lock off unit building to duplex with lock off unit and secondary suite building on this site. Scope of work includes new interior walls, doors, providing adequate structural support for the removed existing loadbearing wall, Plumbing, electrical, Sprinkler, millwork, and finishes. OK for DB per M.Tavanpour OK for Field Review per S.Dugaro Related to: IA-2024-00121 Note: This building is sprinklered (SP-2019-00892. A separate sprinkler permit is required for all related work No strata-titling will be permitted. An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and in hallways serving sleeping units on each storey as per Building Bylaw 9.10.19. Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times. Headroom to be minimum 1950mm over 80% of the suite area and all egress routes.
Source: Vancouver — Issued permits — 2023-2025. Contains information licensed under the Open Government Licence – Vancouver.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.
Sign in to comment.
No comments on this page.