Source: Vancouver — Issued permits — 2020-2022

High Density Housing / Commercial - Addition / Alteration - Interior alterations to replace existing single stage fire alarm panel with a new addressable panel and to provide modernization of the existing elevator to allow for elevator…

Listed on FolioProjects
2026-11-28
Location
222 N TEMPLETON DRIVE, Vancouver, BC V5L 3E4
Application number
BP-2019-05080
Source-reported status
Issued

Application status does not establish construction activity or completion.

Share, broadcast and print
Open broadcast feed

Source information and freshness

Vancouver — Issued permits — 2020-2022 · Last checked 2026-11-28T21:45:12.903458+00:00

Checking a source does not confirm that its records reflect current construction or approvals. Meaningful changes appear in Activity.

Original source record

Contains information licensed under the Open Government Licence – Vancouver. Licence

Summary totals updated 2026-11-28 21:55:16.615545+00. Recent changes appear after the next refresh.

Public Broadcast · screens & websites

Shows only publicly available records. Private records are excluded, even when you are signed in.

Launch Broadcast ↗

Municipal application details

Building permit — Addition / Alteration · BP-2019-05080

High Density Housing / Commercial - Addition / Alteration - Interior alterations to replace existing single stage fire alarm panel with a new addressable panel and to provide modernization of the existing elevator to allow for elevator recall from basement to 3rd floor of this existing 3-storey residential building for CSA-B44 upgrade. Scope of work: - Replace existing conventional FACP with new addressable panel and install new fire alarm annunciator panel. - Upgrade electrical equipment for elevators in the machine rooms to suit new elevator power requirements. - Install new relays and upgrade existing FAS initiation devices to addressable type and to allow for activation of the automatic emergency elevator recall sequence. - Programming of Elevator Recall and FEO functions. ******THIS PERMIT HAS BEEN ISSUED UNDER THE REQUIREMENTS OF VBBL 2019******** Building Review Branch Notes: - Schedule B - Arch. & Elec. submitted by S. M. Miyandoab, P. Eng. - Automatic emergency recall (main - ground floor, alternate - 2nd floor) - No changes are being proposed to the existing FA zones.

Application address
222 N TEMPLETON DRIVE, Vancouver, BC V5L 3E4
Source-reported status
Issued
Source record created
Issued date

Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.

Source data licence and terms of use ↗

View municipal application ↗

These are municipal application records. Their status and dates do not establish current construction progress. Associated addresses do not establish a verified parcel history.

About this project

Permit value (CAD): 23900.00

Type of work: Addition / Alteration

Property use: Dwelling Uses

Specific use: Multiple Dwelling

Area: Grandview-Woodland

Permit issued: 2020-01-10

Permit number created: 2019-11-04

HueFlux feedback

Recorded project feedback. These responses do not establish property condition or represent the whole community.

No feedback yet

Share your view using the controls below.

Positive feedback
Negative feedback

Project polls

Answer specific questions about this project and view the results the owner chooses to share.

View project polls

Poll answers are measured separately from HueFlux feedback.

References

No reference links have been added.

Focus areas

No focus areas have been added.

Comments

New comments are public while this project is public. Earlier members-only comments remain restricted.

Sign in to comment.

No comments on this page.