Project · Public

Building permit — Addition / Alteration — 1638 DRUMMOND DRIVE, Vancouver, BC V6T 1B6

Source: Vancouver — Issued permits — 2023-2025

High Density Housing / Commercial - Addition / Alteration - To construct a two-storey ***PART 5*** Infill Single Detached House (Building 2) and a swimming pool at the rear of the site, having vehicular access from from Drummond Drive.

Listed on FolioProjects
2026-11-27
Location
1638 DRUMMOND DRIVE, Vancouver, BC V6T 1B6
Application number
BP-2024-03371
Source-reported status
Issued

Application status does not establish construction activity or completion.

Share, broadcast and print
Open broadcast feed

Source information and freshness

Vancouver — Issued permits — 2023-2025 · Last checked 2026-11-27T04:25:15.894133+00:00

Checking a source does not confirm that its records reflect current construction or approvals. Meaningful changes appear in Activity.

Original source record

Contains information licensed under the Open Government Licence – Vancouver. Licence

Summary totals updated 2026-11-27 04:34:03.641595+00. Recent changes appear after the next refresh.

Public Broadcast · screens & websites

Shows only publicly available records. Private records are excluded, even when you are signed in.

Launch Broadcast ↗

Municipal application details

Building permit — Addition / Alteration · BP-2024-03371

High Density Housing / Commercial - Addition / Alteration - To construct a two-storey ***PART 5*** Infill Single Detached House (Building 2) and a swimming pool at the rear of the site, having vehicular access from from Drummond Drive. Related to DP-2023-00920, See BP-2024-03361 for Main House. Building Review Branch Notes: 1. Sch A, Sch D, Sch Arch. B, Struct. B and Geo. B are provided 2. Entire building sprinklered to NFPA 13 requirements. 3. All new windows, doors, and skylights shall conform to AAMA/WDMA/CSA101/I.S.2/A440, NAFS. 4. Reviewed under VBBL 2019 Revision #1 for Infill building, May 9th, 2025, related to DP-2025-00169 •\tchanges to the exterior finishes, windows and doors, •\talterations to the roof configuration along the west portion, •\tchanges to the roof and wall details and assemblies, •\taddition of solar panels, •\trevisions to the foundations resulting in an expanded crawl space, •\tminor changes to the interior layout, •\trelocation of the heat pump, •\taddition of gas fireplace Revision #2 for Infill building, July 29, 2025 (No DPMA required) •\tAlternate solution for a change to the sprinkler requirement from NFPA13 to NFPA13D, related to AL-2025-00120 •\tWindow and door revisions (sizes adjusted and one added) •\tShear walls added to floor plans •\tConcrete curb raised 6” on east end with interior furring revised •\tRainscreen changed to drainage mat •\tSoffit changed to exposed rafter tails with related detail updates •\tDetail markers added on A-302 •\tGutters changed from colonial to half-round with updated paint color

Application address
1638 DRUMMOND DRIVE, Vancouver, BC V6T 1B6
Source-reported status
Issued
Source record created
Issued date

Source: Vancouver — Issued permits — 2023-2025. Contains information licensed under the Open Government Licence – Vancouver.

Source data licence and terms of use ↗

View municipal application ↗

These are municipal application records. Their status and dates do not establish current construction progress. Associated addresses do not establish a verified parcel history.

About this project

Permit value (CAD): 493750.00

Type of work: Addition / Alteration

Property use: Dwelling Uses

Specific use: Single Detached House

Area: West Point Grey

Permit issued: 2024-12-20

Permit number created: 2024-09-04

HueFlux feedback

Recorded project feedback. These responses do not establish property condition or represent the whole community.

No feedback yet

Share your view using the controls below.

Positive feedback
Negative feedback

Project polls

Answer specific questions about this project and view the results the owner chooses to share.

View project polls

Poll answers are measured separately from HueFlux feedback.

References

No reference links have been added.

Focus areas

No focus areas have been added.

Comments

New comments are public while this project is public. Earlier members-only comments remain restricted.

Sign in to comment.

No comments on this page.