Building permit — Addition / Alteration · BP-2021-06684
Field Review - Addition / Alteration - 1518 Nanaimo St Interior alterations and a change of use from Retail (Shell) to Health Care Office for a new tenant on the ground floor in this existing mixed-use building on this site. OK for Field Review per S. Dugaro, December 16, 2021 Letter of assurance submitted by: Schedule A & Schedule B (Mechanical & Plumbing): Avi Singh, P.Eng., 604-593-1446 Schedule B (Electrical): Gary Jatana, P.Eng., 604-593-1446 Note: - No change in the number of parking - Building Sprinklered - Building inspector to determine on site is a separate sprinkler permit is required. - Energy Upgrade Exempt: 1st TI Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing). All energy upgrades will be checked during inspections stage. It is the applicant's responsibility to identify and note all required upgrades including energy upgrades on their BP drawings at BP stage.
Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.