Building permit — Addition / Alteration · BP-2021-04424
Field Review - Addition / Alteration - #670, #675, #680, #685 and #690 - 6th floor Interior alterations to provide improvements and to demise #690 into five (5) General Office tenant spaces to be #670,#675, #680, #685 and #690 in this existing commercial building. Scope of work: remove partition walls/doors, construct new demising walls, interior partition walls, doors, finishes, lighting, HVAC, electrical, plumbing and sprinkler work. Letters of Assurance submitted by; Schedule A and Architectural Schedule B, Barry Richard Weih, Architect, ph: 604-685-3529 Mechanical and Plumbing Schedule B, Recep Ahmet Ozata, P.Eng., ph: 604-684-5995 Electrical Schedule B, Roger Dupuis, P.Eng., ph: 604-569-6500 OK for field review as per H. Chow, August 17, 2021. E2 - Lighting - Upgrade to Restricted to Partial Automatic ON (per 9.4.1.1(c) of ASHRAE 90.1-2016 Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing). All energy upgrades will be checked during inspections stage. It is the applicant's responsibility to identify and note all required upgrades including energy upgrades on their BP drawings at BP stage.
Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.