Building permit — New Building · BP-2024-01816
High Density Housing / Commercial - New Building - Multiplex: To construct a "Multiplex" building containing two dwelling units at the front of the site. Revision #1 January 2nd, 2025- (BP-2024-01816, BP-2024-01817, BP-2024-01818, BP-2024-01819) : 1. Stratify lot 2. Delete PMT, BC hydro confirmation provided 3. Alterations at carport at rear buildings 4. Remove sprinkler protection at front buildings at east and west. Two paths of travel are provided. 5. Change 5/8 type "X" gypsum wall board to 1/2" gypsum wall board under the flat roof and deck Revision #2 - to change landscaping, to change the location of the exterior walkways, provide location of the heat pumps, change the exterior cladding of the buildings and add a storage shelf to the carport area. Revision #3 March 26, 2026 / NB 1.Internal revision to show correct address for all buildings. BRB review notes: 1. Building to be sprinklered to NFPA 13D 2. This permit has been reviewed & issued under the requirements of VBBL 2019 BP-2024-01816 - Building A (2FD) BP-2024-01817 - Building B (2FD) BP-2024-01818 - Building C (1FD) BP-2024-01819 - Building D (1FD) *Drawings and documents for site uploaded to BP-2024-01816
Source: Vancouver — Issued permits — 2023-2025. Contains information licensed under the Open Government Licence – Vancouver.