Building permit — Addition / Alteration · DB-2024-02133
Enquiry Centre - Addition / Alteration - Interior alterations and a change of use from single detached house to single detached house with secondary suite with three car parking in the accessory garage and one car parking on parking pad with access from the lane. OK for SIPS per W.Wong Note: This building is sprinklered (SP405384). A separate sprinkler permit is required for all related work No strata-titling will be permitted. An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and in hallways serving sleeping units on each storey as per Building Bylaw 9.10.19. Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times. Headroom to be minimum 1950mm over 80% of the suite area and all egress routes. This permit is for alterations as shown in plans only. Any unauthorized work on this site, existing or otherwise, is neither recognized nor approved and may be subject to enforcement action.
Source: Vancouver — Issued permits — 2023-2025. Contains information licensed under the Open Government Licence – Vancouver.