Building permit — Addition / Alteration · BP-2020-03129
Field Review - Addition / Alteration - Exterior and interior alterations to provide improvements to this existing one family dwelling building on this site. Exterior alterations to add a 4' by 8' landing at the rear, remove rear overhang, replace windows in same openings in west elevation and fill in a window in the east elevation. Scope of work: - Basement - demo interior walls, doors, plumbing fixture and lighting, bathroom update, millwork, new mechanical room, and new boiler - Main fl - demo interiors walls, doors, ceiling plumbing fixtures and lighting, millwork, update kitchen and bathroom - Replace windows on same location and new flooring throughout OK for Field Review per W.Wong, October 7, 2020 Related SW-2020-01412 Schedule B Structural & Geotechnical (permanent & Temp) submitted per Sharat Chande, 604-727-7534 REUP submitted per Peter Cho, 778-316-9053 Scope of work to include energy upgrade in accordance with Article 11.2.1.4 of the 2019 Vancouver Building By-law and as per Energy Efficiency Upgrade Details noted in the Energuide Report.