Building permit — Addition / Alteration · DB-2022-01591
Field Review - Addition / Alteration - To complete work started under DB-2018-04602 (expired) Interior alterations only and change of use from an One-Family Dwelling to an One Family with secondary suite building, with 2 -parking space provided in existing detached garage, having vehicular access off the rear lane. Scope of work is to legalize the secondary suite and to close off the interconnecting stairs Note: No strata-titling will be permitted. An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and within 5m outside each sleeping areas on each storey as per Building Bylaw 9.10.19. Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. Upgrade work under Part 11 (based on value of work – energuide related Part 11.2.1.4.) Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times
Source: Vancouver — Issued permits — 2020-2022. Contains information licensed under the Open Government Licence – Vancouver.