Source: Toronto — Building permits — 2026 onward — part A
6th Floor:-Remove up to seventy-two (72) pendent sprinklers.-Remove up to two (2) fire hose cabinets.-Supply and install up to an additional twenty (20) pendent sprinklers.-Supply and install up to seventy-nine (79) white concealed…
6th Floor:-Remove up to seventy-two (72) pendent sprinklers.-Remove up to two (2) fire hose cabinets.-Supply and install up to an additional twenty (20) pendent sprinklers.-Supply and install up to seventy-nine (79) white concealed pendent sprinklers.-Supply and install up to seven (7) phone booth sprinklers.-Supply and install up to two (2) upright sprinklers.-Supply and install up to four (4) fire hose cabinets.7th Floor:-Remove up to seventy-six (76) pendent sprinklers.-Remove up to two (2) fire hose cabinets.-Supply and install up to an additional twenty (20) pendent sprinklers.-Supply and install up to eighty-one (81) white concealed pendent sprinklers.-Supply and install up to seven (7) phone booth sprinklers.-Supply and install up to two (2) upright sprinklers.-Supply and install up to three (3) fire hose cabinets.8th Floor:-Remove up to eighty-five (85) pendent sprinklers.-Remove up to two (2) fire hose cabinets.-Supply and install up to an additional twenty (20) pendent sprinklers.-Supply and install up to eighty-one (81) white concealed pendent sprinklers.-Supply and install up to seven (7) phone booth sprinklers.-Supply and install up to two (2) upright sprinklers.-Supply and install up to four (4) fire hose cabinets.17th Floor:-Remove up toone hundred forty-one (141) pendent sprinklers.-Remove up to one (1) fire hose cabinets.-Supply and install up to an additional twenty (20) pendent sprinklers.-Supply and install up to one hundred forty-two (142) white concealed pendent sprinklers.-Supply and install up to ten (10) phone booth sprinklers.-Supply and install up to two (2) upright sprinklers.-Supply and install up to two (2) fire hose cabinets. Revision: 00. Structure: Office. Work: Sprinklers. Current use: Office. Proposed use: Office. Declared construction value (CAD): 549,800.00.
Application address
200 BAY ST
Source-reported status
Application Acceptable
Application submitted
Source: Toronto — Building permits — 2026 onward — part A. Source: Toronto open municipal data. Adapted for FolioProjects; no municipal endorsement implied.
These are municipal application records. Their status and dates do not establish current construction progress. Associated addresses do not establish a verified parcel history.
These applications share an address listed by the municipality. They remain separate records; this does not confirm that they are phases of one development.
Showing a limited selection of address matches. Search the application address for more records.
About this project
Revision: 00
Structure: Office
Work: Sprinklers
Current use: Office
Proposed use: Office
Declared construction value (CAD): 549,800.00
HueFlux feedback
Recorded project feedback. These responses do not establish property condition or represent the whole community.
Essential cookies keep FolioProjects working. With your permission, Mouseflow records visits to selected public marketing pages. Recording is disabled when you are signed in and on private pages.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.
Sign in to comment.