Project · Public

AS Alternative Solution — 0 SHEPPARD AVE W, Toronto

Source: Toronto — Building permits — 2026 onward — part B

This report has been prepared for 4800 Yonge Limited (Client) to develop an Alternative Solution to the OBC high- rise requirement to provide 2 h fire separated vestibules between one elevator shaft, which serves above-grade and…

Listed on FolioProjects
2026-11-22
Location
0 SHEPPARD AVE W
Application number
26 104080 ALT
Source-reported status
Approved
Application date
2026-01-13

Application status does not establish construction activity or completion.

Share, broadcast and print
Open broadcast feed

Source information and freshness

Toronto — Building permits — 2026 onward — part B · Last checked 2026-11-22T21:40:14.977533+00:00

Checking a source does not confirm that its records reflect current construction or approvals. Meaningful changes appear in Activity.

Original source record

Contains information licensed under the Open Government Licence – Toronto. Adapted for FolioProjects; no municipal endorsement implied. Licence

Summary totals updated 2026-11-22 21:51:15.264015+00. Recent changes appear after the next refresh.

Public Broadcast · screens & websites

Shows only publicly available records. Private records are excluded, even when you are signed in.

Launch Broadcast ↗

Municipal application details

AS Alternative Solution · 26 104080 ALT

This report has been prepared for 4800 Yonge Limited (Client) to develop an Alternative Solution to the OBC high- rise requirement to provide 2 h fire separated vestibules between one elevator shaft, which serves above-grade and below-grade levels, and the remainder of the floor area on Levels P3 through to Pl of the proposed building at 4800 Yonge Street in Toronto, Ontario. Specifically, it is proposed to provide 2 h fire separated vestibules to serve the elevator shaft on the above-grade levels, Levels 1 through 7, in lieu of providing 2 h fire separated vestibules on the below-grade levels, Level P3 through to Pl, as an alternative to complying with below-grade elevator protection. Further, it is proposed for the vestibules serving the elevator to have doors that swing inward (i.e. against the direction of exit travel). The elevator shaft below-grade opens into mechanical rooms on Levels P3 to Pl where spatial constraints prevent the construction of an elevator vestibule within these rooms. Revision: 00. Work: Alternative Solution.

Application address
0 SHEPPARD AVE W
Source-reported status
Approved
Application submitted
Source final date

Source: Toronto — Building permits — 2026 onward — part B. Source: Toronto open municipal data. Adapted for FolioProjects; no municipal endorsement implied.

Source data licence and terms of use ↗

View municipal application ↗

These are municipal application records. Their status and dates do not establish current construction progress. Associated addresses do not establish a verified parcel history.

About this project

Revision: 00

Work: Alternative Solution

HueFlux feedback

Recorded project feedback. These responses do not establish property condition or represent the whole community.

No feedback yet

Share your view using the controls below.

Positive feedback
Negative feedback

Project polls

Answer specific questions about this project and view the results the owner chooses to share.

View project polls

Poll answers are measured separately from HueFlux feedback.

References

No reference links have been added.

Focus areas

No focus areas have been added.

Comments

New comments are public while this project is public. Earlier members-only comments remain restricted.

Sign in to comment.

No comments on this page.