Commercial / Multi / Industrial · BP127528
Inspection Permit for Building C at 6020 Linley Valley Drive. Building C: Area 738.61 m2 5 storey Group C 3.2.2.50 over first floor parkade. GFA 3660.20m2 Sprinklered to NFPA 13 with Standpipe and Fire Alarm system, Combustible/Non Combustible, 2hr FRR/FS between parkade and residential units, 1.5hr FRR/FS between parkade and other occupancies, 1hr FRR/FS 57 STC party walls and elevator walls, 1hr FRR/FS 58 STC between units and corridor. All doors in fire-separations to be self-closing. Alternative Solution for exit exposure protection with water curtain sprinklers. Main Permit: BP127522 REVISION 2023-DEC-22: See main permit. REVISION 2024-JUL-10: See main permit.
Other addresses listed in this application: 6030 LINLEY VALLEY DRIVE.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.