Commercial / Multi / Industrial · BP121097
Nanaimo Memory Care, Group B2 , 4 Storey (high building by code) 77 sleeping units , noncombustible construction, sprinklered , fire alarm, building area (footprint) for code purpose = 1203.46 m2, Total floor area including stairs and elevator = 4660.75m2 2 hr FRR/FS for the floor assemblies and loadbearing supports, exits enclosures, elevator shafts, emergency generator room, unsprinklered electrical room. 1 hr FRR/FS for sleeping room zones, service rooms with fuel fire appliance, and combustible refuse room. REVISION February 2, 2016 , New drawings issued, Summary of the list of Revisions by Barrett Dembeck, Architects and SRC Engineering Consultants attached to drawings . Revised drawings list also attached . REVISION April 26, 16 - Revision to some windows as indicated on plans. REVISION July 22, 2016 - Change to fourth floor patio doors. REVISION Apr 11, 17 - Remove Alt Sol schedule B.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.