Commercial / Multi-Res Alteration · BP131833
Alteration to address illegal construction (CIB06369). Work includes addition of 2nd storey over engineered storage racking system and additional wood framed storage area over break room, interior partition walls to create separate workshops, lunch room and storage areas, new exterior overhead doors, exterior addition for storage area, installation of new fire alarm. Building classification: 2024 BCBC Group F2 3.2.2.81, combustible or non-combustible construction, sprinklered with fire alarm. Previously approved alternative solution (BP120521) for fire resistance rating of exterior walls. The alternative solution includes water curtain sprinklers on interior face of the south and east exterior walls where 1-hr and 2-hr FRR are required for exposed building face.
Other addresses listed in this application: 3851 SHENTON ROAD.