Commercial / Multi-Res Alteration · BP127149
(CITY SARC BLDG) - Work includes new interior partition walls for new meeting rooms and to realign offices on each floor. Mechanical adjustments to suit new layout. Sprinkler work includes relocating 2 heads and adding 2 heads on the 2nd floor. Adding 2 heads and relocating 4 heads on the third floor. Building Description, Part 3, Governing article, 3.2.2.54, Office building, Group D, Three storeys with Parking Garage, Group F3 on ~ half of the 1st storey. Building sprinklered with fire alarm. First storey, Group D = 792 m2 plus Group F3 = 788 m2; Second Storey, Group D, 1542 m2; Third Storey = 1672 m2 . Gross Floor area (Group D) = 4006 m2 plus Parking Garage (Group F3) = 788 m2. Floor assemblies and load bearing non-combustible construction as per 3.2.2.54; Exits = 45 min. FRR/FS; 1.5 hr FRR/FS between F3 and Group D. 45 metre TD. Elevator and machine room 45 min FRR/FS; Janitor room FS, Occupant load = 430 persons,