Commercial / Multi-Res Alteration · BP129177
(DLX Cantina - The Copper Pot) Unit 130 Group A2, 270m2. Commercial alteration to create new neighborhood pub, dividing existing shell into two CRUs. New pluming facilities include 1 grease interceptor, 24 new fixtures (incl. 6 WCs, 4 lavatories, 1 mop sink and a new commercial kitchen and associated NFPA 96 kitchen hood. 2hr FRR/FS required for mechanical shaft to new RTU. Sprinkler changes include 3 new sprinkler heads within design area, and relocation of other heads. Additional permit required to Occupy adjacent/ remaining separate CRU. Existing Building Classification: Group C 3.2.2.50, Group A2 3.2.2.24 (Shell only), 1731m2 building area, sprinklered with Fire Alarm System. Key FRR /FS are 1 Hour FRR/FS 50 STC between residential suites and 55 STC between residential suites and elevators. 1hr FRR/FS for public corridor, floor/roof assemblies and loadbearing supports and exits. 2 hour FRR/FS 55 STC between residential suites and Group A2.
Other addresses listed in this application: 300 HOWARD AVENUE.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.
Sign in to comment.
No comments on this page.