Commercial / Multi-Res Alteration · BP128839
Interior renovations to create cannabis retail store. Scope of work includes building interior partition walls, installing interior doors, and t-bar ceiling panels. Relocation of 6 and addition of 4 sprinkler heads. Floor area 147.4 m2. Existing Building: 1992 BCBC 3.2.2.43. 2028m2 Group E occupancy sprinklered (with fire alarm) one storey facing 3 streets, combustible construction, 45min. FRR required for floors and supports, no rating @ roof. Rear wall spatial separation requirements - 2hr. FRR with non-combustible cladding; wall @ loading area setback 22' no FRR required. Equivalency submitted by Protection Engineering Inc. adding fast response sprinklers to the entire building and supplying a 1hr 10min. FRR from both sides of the rear exterior wall.
Other addresses listed in this application: 140 TERMINAL AVENUE.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.