Commercial / Multi-Res Alteration · BP128556
"Change of use" from Group E to Group D. Unit 6 (Maxx Insurance). Work includes installation of one additional universal washroom and new office partitions. Suite area 117m2. 2 existing exits. Max travel distance 40m. Max occupant load 10 people based single universal washroom. Minimum 45min FRR/FS required to be maintained to exits, floor/ceiling and supporting structures. Existing building classification; 2006 BCBC 3.2.2.55 Group D, 776.6m2, two storey, combustible or non-combustible, unsprinklered, minimum 45min FRR/FS required for exits, floors and supporting assemblies. 1hr FRR/FS currently provided between Units 5/6/exits, and Units 3/6. REVISION: 2023-MAR-22 - remove walls, remove existing washroom and reduce occupant load to 10. REVISION 2023-MAY-10 - add office partitions.
Other addresses listed in this application: 1611 BOWEN ROAD.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.