Project · Public

Leasehold Improvements — 101, 102, 103-1621 Dufferin Crescent (Nanaimo Dental Specialists), Nanaimo

Source: City of Nanaimo — Planning, building, demolition and subdivision records

(Nanaimo Dental Specialists) Combining three CRU's to create unit #101 for Group D (dental office).Unit Floor area 325 m2. Installing: 9 sinks, Removing: 7 sinks,2 toilets and 1 clothes washer. Relocating sprinkler heads. Existing building: BCBC 2012 3.2.2.65 Group E, 3.2.2.24, Group A2 and 3.2.2.59 Group D superimposed major occupancies. 3 storey, non-combustible construction, sprinklers and fire alarm. 1 hour FRR/FS floor assembly required above the first storey including supporting construction. O Hr. FRR/FS required above the second storey and roof. 1.5 hrs FRR/FS to parking garage. 2763 m2 total on 3 floors, with 1353m2 parking garage(BCBC building area =2274 m2) 2024-APR-16 REVISION: Add sink to lobby area, add rough-in for sink in sterilization room.

Listed on FolioProjects
2026-11-13
Location
101, 102, 103-1621 Dufferin Crescent (Nanaimo Dental Specialists)
Application number
BP129536
Source-reported status
COMPLETED
Application date
2023-09-09

Application status does not establish construction activity or completion.

Share, broadcast and print
Open broadcast feed

Municipal application details

Leasehold Improvements · BP129536

(Nanaimo Dental Specialists) Combining three CRU's to create unit #101 for Group D (dental office).Unit Floor area 325 m2. Installing: 9 sinks, Removing: 7 sinks,2 toilets and 1 clothes washer. Relocating sprinkler heads. Existing building: BCBC 2012 3.2.2.65 Group E, 3.2.2.24, Group A2 and 3.2.2.59 Group D superimposed major occupancies. 3 storey, non-combustible construction, sprinklers and fire alarm. 1 hour FRR/FS floor assembly required above the first storey including supporting construction. O Hr. FRR/FS required above the second storey and roof. 1.5 hrs FRR/FS to parking garage. 2763 m2 total on 3 floors, with 1353m2 parking garage(BCBC building area =2274 m2) 2024-APR-16 REVISION: Add sink to lobby area, add rough-in for sink in sterilization room.

Application address
101, 102, 103-1621 Dufferin Crescent (Nanaimo Dental Specialists)
Source-reported status
COMPLETED
Application submitted
Issued date
Source final date
Source expiry date

Other addresses listed in this application: 101 1621 DUFFERIN CRESCENT; 102 1621 DUFFERIN CRESCENT.

Source: City of Nanaimo — Planning, building, demolition and subdivision records.

View municipal application ↗

These are municipal application records. Their status and dates do not establish current construction progress. Associated addresses do not establish a verified parcel history.

Public Broadcast · screens & websites

Shows only publicly available records. Private records are excluded, even when you are signed in.

Launch Broadcast ↗

About this project

Leasehold Improvements · BP129536
(Nanaimo Dental Specialists) Combining three CRU's to create unit #101 for Group D (dental office).Unit Floor area 325 m2. Installing: 9 sinks, Removing: 7 sinks,2 toilets and 1 clothes washer. Relocating sprinkler heads. Existing building: BCBC 2012 3.2.2.65 Group E, 3.2.2.24, Group A2 and 3.2.2.59 Group D superimposed major occupancies. 3 storey, non-combustible construction, sprinklers and fire alarm. 1 hour FRR/FS floor assembly required above the first storey including supporting construction. O Hr. FRR/FS required above the second storey and roof. 1.5 hrs FRR/FS to parking garage. 2763 m2 total on 3 floors, with 1353m2 parking garage(BCBC building area =2274 m2) 2024-APR-16 REVISION: Add sink to lobby area, add rough-in for sink in sterilization room.
Source-reported status: COMPLETED. Application status does not establish construction activity or completion.
Application date: 2023-09-09.
Permit issue date: 2023-10-27.
Source final date: 2024-05-27.
Source expiry date: 2025-10-27.
Addresses listed by the municipality: 101 1621 DUFFERIN CRESCENT; 102 1621 DUFFERIN CRESCENT. These are source-listed associations, not a verified parcel history.
Municipal application source
City of Nanaimo, What's Building public application CSV. The City is the data source, not necessarily the project owner. This profile is not managed or endorsed by the City.
Source data licence and terms of use

HueFlux feedback

Recorded project feedback. These responses do not establish property condition or represent the whole community.

Feedback totals are unavailable.

Positive feedback
Negative feedback

Project polls

Answer specific questions about this project and view the results the owner chooses to share.

View project polls

Poll answers are measured separately from HueFlux feedback.

References

No reference links have been added.

Focus areas

No focus areas have been added.

Comments

New comments are public while this project is public. Earlier members-only comments remain restricted.

Sign in to comment.

No comments on this page.