Commercial / Multi-Res Alteration · BP130232
Construction of a storage and mechanical room within an underground parkade. Work includes construction of 2 Hour FRR/FS interior partition walls, no sprinkler changes proposed. Bldg description BCBC2006 3.2.2.45, 4 Storey, sprinklered to NFPA 13R and NFPA 13 in parking garage, fire alarm, combustible Group C, Building area = 1198 m2 x 3 storeys & Group F3 = 915m2. Group C with Group F3 (Storage Garage). Subsidiary occupancies to Group C are dining room, activity room, lounge. Floor assemblies 1 Hour FRR/FS, 50 STM. Parking storage garage 1.5 hr FRR/FS for exits & between other occupancies . Vestibule 0 hr. FS required to parkade. Duct shafts, 45 min FRR/FS, Exits 1 hour FRR/FS, Residential Suites doors only 20 min ULC labelled FPR. other door 45min FPR. 1 hr public corridor to suites. Accessible to front entrance. Alternative solutions: Via water curtain sprinkler system for exit exposure for rear exit stairs & exit adjacent to Robarts Street .