Commercial / Multi / Industrial · BP131053
Certified Professional Building Permit Process Construction of a 2-Storey over crawlspace institutional building. Building Classification Group A-2 (School) 3.2.2.27. 431.3 m2 building area, combustible construction, sprinklered to NFPA 13 with single stage fire alarm system. Key FS/FRR are: 45min FRR for North exposing building faces, 45min FS/FRR elevator and exit separation, 0 hr FS/FRR smoke separation at janitor closet. Total GFA 858.78m2. Additional scope of work includes the installation of a non-combustible(steel) non-enclosed covered walkway structure and canopies REVISION: 2026-FEB-17: Alternative Solution for deviations from the prescriptive British Columbia Building Code requirements for spatial separation between the new and existing building. REVISION: 2026-AUG-24: New Engineer of Record for Electrical engineering design changes during construction and field review.
Other addresses listed in this application: 1503 CRANBERRY AVENUE.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.