Commercial / Multi-Res Alteration · BP129507
(Starbucks) Change of Use from Group A-2 to Group E (grab-and-go) use. Building major occupancy revised to BCBC 2018 Group E. Scope of work includes complete suite renovation with single accessible washroom, relocation of interior partition walls, new exit door. Sprinkler modifications include relocation of 8 heads, deletion of 4 heads, replacement of 1 head. Suite area: 140.4 m2. Existing 2-hr FRR/FS (45-min req'd) between adjacent Group E occupancies. Interior accessible routes to CSA B651-12, all other provisions to BCBC 2018. REVISION 2024-SEPT-19: Change of electrical engineer of record. Building Classification: BCBC 2018 3.2.2.69. Group E, one storey, 962.5 m2 building area, sprinklered to NFPA 13, with fire alarm. Combustible and noncombustible construction, 45-min FRR floors/walls/columns/arches. Seismic performance to 2015 NBC Structural Commentary L Level 2.
Other addresses listed in this application: 3200 ISLAND HIGHWAY N.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.