Leasehold Improvements · BP131639
Completion of shell space 103 (Northwood Pelvic Health and Wellness) Group D 133m2 Work includes: Installation of a universal WC; 1 hwt; 1 auto washer; 1 toilet and 1 wash basin. Interior partition walls to support offices and reception area. To Resolve CIB06566. Existing Bldg Classification: BCBC2006 3.2.2.54 Group D and 3.2.2.60 Group E, superimposed major occupancies, Building area 1203 m², sprinklered with fire alarm, combustible and non-combustible construction OK, FS with no FRR for floor between level 2 to 3 of non-combustible construction, 45 min. FS for other floors (3.2.2.60.), 45 min. FRR for combustible supports of floor system. Alternative Solution for exit exposure & glass in exit stair & btwn lobby & storage garage on first floor by GHL.
Other addresses listed in this application: 125 WALLACE STREET.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.