Leasehold Improvements · BP129225
Tenant Improvement, Unit 205 (Vince Nails Spa Limited), Group D, 115.6m2. Convert from existing hair salon to new nail salon. 2-hr FRR/FS firewall on wall adjacent to Suite 203 and 1 hour FRR/FS for all other suite separations. Brooks Landing - 12,981m2, Group E building, sprinklered, combustible construction, fire alarm, BCBC 2018 - 3.2.2.67, subdivided into 3 separate buildings with two 2-hr firewalls with fast response sprinklers in suites adjacent to firewalls by 1996 equivalency (BP046573, modified in BP125557). Equivalency requires 1-hr FRR/FS between D/E and A2/D occupancies, and 2-hr FRR/FS between A2/E occupancies. To resolve CIB06037 stop work order
Other addresses listed in this application: 2000 ISLAND HIGHWAY N.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.