Source: City of Nanaimo — Planning, building, demolition and subdivision records
Construction of parkade security screen, overhead garage gate installation and installation of required exit doors c/w exit signage and panic hardware. Existing Building: 2012 BCBC, 6 storey 159 unit multi-family development with a parking garage. Includes subsidiary commercial kitchen and dining facilities. Sprinklered with Fire Alarm. North building (alternative solution for building classification): 3.2.2.50, Group C, 1082.8 m2, 6 storey , mixed combustible and non-combustible constriction with a 3.2.2.80, Group F3, 1473 m2 parkade. 2 hr FRR Firewall between north and south building. South building: 3.2.2.50, Group C, 1193.5 m2, 6 storey, Combustible Construction.
Construction of parkade security screen, overhead garage gate installation and installation of required exit doors c/w exit signage and panic hardware. Existing Building: 2012 BCBC, 6 storey 159 unit multi-family development with a parking garage. Includes subsidiary commercial kitchen and dining facilities. Sprinklered with Fire Alarm. North building (alternative solution for building classification): 3.2.2.50, Group C, 1082.8 m2, 6 storey , mixed combustible and non-combustible constriction with a 3.2.2.80, Group F3, 1473 m2 parkade. 2 hr FRR Firewall between north and south building. South building: 3.2.2.50, Group C, 1193.5 m2, 6 storey, Combustible Construction.
Application address
10 Buttertubs Drive
Source-reported status
COMPLETED
Application submitted
Issued date
Source final date
Source expiry date
Source: City of Nanaimo — Planning, building, demolition and subdivision records.
These are municipal application records. Their status and dates do not establish current construction progress. Associated addresses do not establish a verified parcel history.
These applications share an address listed by the municipality. They remain separate records; this does not confirm that they are phases of one development.
Public Broadcast · screens & websites
Shows only publicly available records. Private records are excluded, even when you are signed in.
Commercial / Multi-Res Alteration · BP128196
Construction of parkade security screen, overhead garage gate installation and installation of required exit doors c/w exit signage and panic hardware. Existing Building: 2012 BCBC, 6 storey 159 unit multi-family development with a parking garage. Includes subsidiary commercial kitchen and dining facilities. Sprinklered with Fire Alarm. North building (alternative solution for building classification): 3.2.2.50, Group C, 1082.8 m2, 6 storey , mixed combustible and non-combustible constriction with a 3.2.2.80, Group F3, 1473 m2 parkade. 2 hr FRR Firewall between north and south building. South building: 3.2.2.50, Group C, 1193.5 m2, 6 storey, Combustible Construction.
Source-reported status: COMPLETED. Application status does not establish construction activity or completion.
Application date: 2022-01-19.
Permit issue date: 2022-05-05.
Source final date: 2023-07-11.
Source expiry date: 2024-05-05.
Addresses listed by the municipality: 10 BUTTERTUBS DRIVE. These are source-listed associations, not a verified parcel history.
Municipal application source
City of Nanaimo, What's Building public application CSV. The City is the data source, not necessarily the project owner. This profile is not managed or endorsed by the City.
Source data licence and terms of use
HueFlux feedback
Recorded project feedback. These responses do not establish property condition or represent the whole community.
Essential cookies keep FolioProjects working. With your permission, Mouseflow records visits to selected public marketing pages. Recording is disabled when you are signed in and on private pages.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.
Sign in to comment.