Commercial / Multi / Industrial · BP125163
INSPECTIONS ONLY North Buildings: Construction of a 3 storey commercial/multi-family 1753.26 m2 building with 14 residential units and 3 commercial units. Classified as 3.2.2.53. C Occupancy, 3.2.2.59. D Occupancy. Combustible construction, sprinklered, fire alarm system. 2 hr FRR/FS provided between residential and commercial, 2 hr FRR/FS provided between units 101 (Group D – Low A2) and 103 (Group D) and 45 min FRR/FS required between units 103 (Group D) and unit105 (Group D), 1hr FRR/FS required between residential units. and Construction of a 4 unit, 2 storey multi-family 204.39 m2 building. Classified under 3.2.2.53. Sprinklered, combustible construction building with fire alarm 1 hr FRR/FS between units and a non-combustible wall with a 1 hr FRR is required along the east property line of the north building. Alternative solution for Exit Protection and Egress from 2 storey dwelling units above commercial units.
Other addresses listed in this application: 507 MILTON STREET.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.