Commercial / Multi-Res Alteration · BP131971
(Blowers and Grafton) Unit 110 – First tenant Improvement for a Restaurant tenant (Group A2) to occupy this commercial shell space. Total GFA: 684m2 (1st storey) and 129m2 (2nd storey). Scope of work includes the construction of an interior flight of stairs to access the existing balcony and an interior flight of stairs to access the existing 2nd floor, commercial kitchen designed to NFPA 96, existing fire-separations to be maintained, NFPA 13 FSS system revised to suit layout. Proposed occupant load: 356. Existing Building: (BP128857) BLDG 1 (Public Market) BCBC 2018 3.2.2.26 / .63 / .67 Group A2/D/E, 2,135 m2 building area, Sprinklered, single-stage fire alarm, 2-storey, combustible construction / 45-min FS/FRR floor assemblies / 45-min. FS/FRR load-bearing supports.
Other addresses listed in this application: 1840 STEWART AVENUE.