Commercial / Multi-Res Alteration · BP130011
Change of use from Group E to Group D (Long Lake Dental), 420 m2, work includes adding interior partition walls to create 17 work stations, staff lunchroom, waiting area, offices and additional WCs, extending the required fire separation to the underside of the roof deck. Changes to plumbing system includes relocating 2 toilets, 2 washbasins and installation of 1 toilet. Existing building is 761.62 m2, ends at firewall, BCBC 2012 Group A2, 3.2.2.28. one storey, 1200 m2 facing 3 streets (doubled size permitted provided no basement and min.1 hr FS between suites), BCBC2024 Group D- 3.2.2.64. combustible const, Major occupancies in building E, D and A-2 REVISION: delete proposed sanitary pump as gravity connections available.
Other addresses listed in this application: 4890 RUTHERFORD ROAD.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.